ACSR CONDUCTOR acsr cable acsr wire

ACSR CONDUCTOR acsr cable acsr wire
Product Detailed
One of the biggest cable manufacturer in China, cheaper price&good quality sales in Middle East,Africa,Chile,Brazil,bolivia... ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied. All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 (AAAC) Conductor as per ASTM-B-399-1992 (AAAC) Conductor as per BS-3242-1970 (AAAC) Conductor IS: 398-IV-1994 (ACSR) as per ASTM-B-233-1992 (AAC) as per BS-215-1-1970 (AAC) as per IS-398-1: 1976 (AAC) as per ASTM-B-231-1990 (ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 (ACSR) BS-215-II-1970 (AACSR) as per IEC-1089-1191 AAC(All aluminum conductor) are suited for overhead power line.

ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied. All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 (AAAC) Conductor as per ASTM-B-399-1992 (AAAC) Conductor as per BS-3242-1970 (AAAC) Conductor IS: 398-IV-1994 (ACSR) as per ASTM-B-233-1992 (AAC) as per BS-215-1-1970 (AAC) as per IS-398-1: 1976 (AAC) as per ASTM-B-231-1990 (ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 (ACSR) BS-215-II-1970 (AACSR) as per IEC-1089-1191 AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Construction Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. Specifications ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) Notes Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.The data sheets below show part spec of IEC61089

Code NumberStranding&Wire DiameterApproxSectional AreaApproxWeightBreaking LoadDC Resistance
Overall
AlSteelDiameterAlSteelTotal
mmmmmmmm 2mm 2mm 2Kg/kmKNOhm/km
166/1.841/1.845.53162.6718.764.66.081.7934
256/2.301/2.306.91254.1729.2100.99.131.1478
1006/4.611/4.6113.810016.7117403.834.330.2869
12518/2.971/2.9714.91256.94132397.929.170.2304
16018/3.361/3.3616.81608.89169509.336.180.18
25022/3.807/2.1121.625024.6275880.668.720.1154
40054/3.077/3.0727.640051.94521510.3123.040.0723
45054/3.267/3.2629.345058.35081699.1138.420.0643
50054/3.437/3.4330.950064.85651887.9153.80.0578
56054/3.6319/2.1832.756070.96312103.4172.590.0516
63054/3.8519/2.3134.763079.87102366.3191.770.0459
71054/4.0919/2.4536.871089.98002666.8216.120.0407
80072/3.767/2.5137.680034.68352480.2167.410.0361
90072/3.997/2.6639.990039.99392790.2188.330.0321